CHAPTER 5 DIRECT SUPPORT MAINTENANCE - TM-5-4220-227-14_194
Table 5-1.  Direct Support Troubleshooting Procedures (Cont).

TM-5-4220-227-14 MK12 Surface Supported Diving System (SSDS) (NSN 4220-01-097-5674) Manual
Page Navigation
  176    177    178    179    180  181  182    183    184    185    186  
TM 5-4220-227-14 5-5.  Direct Support Troubleshooting Procedures.   Table 5-1 lists the common malfunctions that may be found during operation.  Refer to symptom index to locate the troubleshooting procedures for the malfunction.  This manual cannot list all malfunctions that may occur, nor all test or inspections and corrective actions.  If a malfunction is not corrected by listed corrective actions, notify your supervisor. SYMPTOM INDEX Symptom Page 1. Recompression chamber slowly loses air pressure ................................................... 5-4 2. Recompression chamber overpressurizes ................................................................ 5-4 3. Heater/chiller fails to function ................................................................................... 5-5 Table 5-1.  Direct Support Troubleshooting Procedures. MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1.  RECOMPRESSION CHAMBER SLOWLY LOSES AIR PRESSURE. Perform   leak   test   on   door   seals,   view   ports,   oxygen/air   penetrator   parts,   heater/chiller/fluid   and   electrical penetrator  parts,  accessory  blanking  plate  parts,  air  supply  and  exhaust  manifold  penetrator  parts,  valves  and piping. a.  Repair or report malfunction to General Support Maintenance as required. b.  Make adjustments to air supply source to insure adequate air supply. 2.  RECOMPRESSION CHAMBER OVERPRESSURIZES. Step  1.    Ensure  that  the  ALP-005,  ALP-006  I/L  and  ALP-009,  ALP-010  O/L  primary  and  secondary  air  supply valves are closed and then check operation of ELP-007, ELP-008 I/L and ELP-011, ELP-012 O/L primary and secondary air exhaust valves.  These valves may be closed tight preventing any air flow through the chamber. Open  ELP-007  and  ALP-005,  the  primary  exhaust  valves.    Adjust  the  valves  to  produce  the desired depth and flow rate. Step 2.  Check ALP-004 pressure relief isolator valve.  This valve may be closed, preventing flow of pressure to APR-004 the pressure relief valve. Open ALP-004 pressure relief isolator valve.  It should be secured in the open position with safety wire. 5-2







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.