Figure 5-1.  Medical Lock (M/L) Outer Door Assembly, Replace
Figure 5-2.  Medical Lock (M/L) Outer Door Assembly, Repair.

TM-5-4220-227-14 MK12 Surface Supported Diving System (SSDS) (NSN 4220-01-097-5674) Manual
Page Navigation
  181    182    183    184    185  186  187    188    189    190    191  
TM 5-4220-227-14 5-7.  Medical Lock (M/L) Outer Door Assembly (Cont). b.  Repair.  (figure 5-2) (1)   Remove door assembly, see para. a. above. (2)   Remove two hinge supports (1) from hinge assembly (2). (3)   Remove two flanged bearing bushing (3) from hinge supports (1). (4)   Remove tapered pin (4) from handle assembly (5). (5)   Hold door assembly (6) and remove handle assembly (5) from hinge assembly (2). (6)   Remove door assembly (6) with flanged bearing bushing (7). (7)   Remove flanged bearing bushing (7). (8)   Clean all components using nonionic detergent cleaner and rinse with clean distilled water. (9)   Inspect all items and replace all items that are bent, cracked, worn or otherwise damaged. (10) Using lint free cloth, remove grease from handle assembly (5), hinge assembly (2) and door assembly (6). (11) Apply grease to flanged bearing bushing (7) and install on door assembly (6). (12) Install door assembly (6) into hinge assembly (2). (13) Install handle assembly (5) while lining up holes for tapered pin (4). (14) Install tapered pin (4) into handle assembly (5). (15) Install two flanged bearing bushings (3) in hinge supports (1). (16) Install two hinge supports (1) on hinge assembly (2). (17) Install door assembly, see para. a. above. 5-8







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.