  292    293    294    295    296  297  298    299    300    301    302  
TM 5-4220-227-14 5-39.  Dual Hose Assembly. This task covers: Replace b.  Repair INITIAL SETUP Tools Materials/Parts (Cont) General Mechanic's Tool Kit Distilled Water (Item 9, Appendix E) (NSN 5180-00-177-7033) Bands, Rubber (Item 4, Appendix E) Bags, Plastic (Item 3, Appendix E) Materials/Parts Detergent, Nonionic (Item 8, Appendix E) Dual Hose Assembly Equipment Condition Hose Clamps (2) Gasket Inhalator mask assembly removed (para.  4-50). Cloth, Lint-Free (Item 6, Appendix E) a.  Replace.  (figure 5-59) WARNING To prevent the spread of disease, serious injury and/or death, oxygen breathing systems must be maintained hygienically clean and free from dust, dirt, and all hydrocarbon contamination.  Refer to oxygen system prework procedures para.  4-10 to avoid violating this warning. NOTE If the chamber is pressurized, the oxygen inhalator dual hose assembly may be passed in through M/L. (1) Loosen fitting nut (1) from mask demand regulator connection (2) and remove supply hose (3) and gasket (4). Discard gasket. (2) Remove  hose  clamp  (5)  from  exhaust  regulator  connection  (6)  and  remove  exhaust  hose  (7).    Discard  hose clamp. (3) Install exhaust hose (7) on exhaust regulator connection (6) and secure with new hose clamp (5). (4) Install supply hose (3) and new gasket (4) on mask demand regulator connection (2) and tighten fitting (1). 5-128







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.