Figure 5-61.  02 and Air Piping, Removal (Sheet 2 of 2).
Figure 5-62.  02 and Air Piping, Installation (Sheet 1 of 2)

TM-5-4220-227-14 MK12 Surface Supported Diving System (SSDS) (NSN 4220-01-097-5674) Manual
Page Navigation
  300    301    302    303    304  305  306    307    308    309    310  
TM 5-4220-227-14 5-40.  02 and Air Piping (Cont). b.  Install.  (figure 5-62) WARNING Leave 1 1/2 threads exposed on fitting when applying  teflon tape.  This will ensure that no   teflon tape will hang down inside the air system.  Teflon tape should be wrapped in such a manner that when  the  fitting  is  tightened  the  tape  will  not  loosen.    Failure  to  wrap    teflon  tape  correctly  may result in contamination or blockage of the air system and subsequent possible injury or death to the diver. (1) Apply teflon tape to all pipe threads. NOTE There are two lines going to the BIBS manifold in the O/L and I/L.  Installation of each line is the same. (2) Install line (1) and tighten fitting nuts (2) and (3). (3) Install line (4) and tighten fitting nuts (5) and (6). 5-136