Figure 5-71.  Depth Gages, Replace
Caisson Gages

TM-5-4220-227-14 MK12 Surface Supported Diving System (SSDS) (NSN 4220-01-097-5674) Manual
Page Navigation
  324    325    326    327    328  329  330    331    332    333    334  
TM 5-4220-227-14 WARNING Leave 1 1/2 threads exposed on fitting when applying teflon tape.  This will ensure that no teflon tape will hang down inside the air system.  Teflon tape should be wrapped in such a manner that when the fitting is tightened  the  tape  will  not  loosen.    Failure  to  wrap  teflon  tape  correctly  may  result  in  contamination  or blockage of the air system and subsequent possible injury or death to the diver. (5) Apply teflon tape to all pipe threads. (6) Install adapter (12) on new depth gage (6). (7) Install gage (6) in place and hand tighten fitting (7) making sure not to cross-thread. (8) Install three screws (10), lockwashers (9), and nuts (8). (9) Tighten fitting (7) on depth gage (6). (10) Open isolator valve (5) to depth gage (6). (11) Remove two pins (4), supports (3), close enclosure door (2), and secure with two latches (1). 5-163