Figure 6-26.  Control Box, Replace
Figure 6-27.  Control Box Electrical, Schematic

TM-5-4220-227-14 MK12 Surface Supported Diving System (SSDS) (NSN 4220-01-097-5674) Manual
Page Navigation
  376    377    378    379    380  381  382    383    384    385    386  
TM 5-4220-227-14 6-14.  Control Box Assembly. b.  Repair. (1)    Test relay.  (figure 6-27) (a)  Remove cover of control box (para.  a.  above). WARNING Serious  injury  or  death  may  result  from  electrical  shock.    Ensure  that  the  220  and  110  Vac  external electrical power sources are disconnected before working inside the heater/chiller module. (b)    Apply  power  to  chamber.    Using  a  multimeter,  test  for  voltage  across  terminals  1  and  2  of  relay  (refer  to schematic, figure 6-27). (c)    Turn SWT-022 ON and check for voltage across terminals S and M.  If no voltage is read, replace relay. (d)    Disconnect chamber from power source. (e)    Replace cover of control box (para. a. above). 6-56