Figure 2-4.  Scrubber Assembly, Service.
Figure 2-5.  Recompression Chamber Operating Procedure Flowchart

TM-5-4220-227-14 MK12 Surface Supported Diving System (SSDS) (NSN 4220-01-097-5674) Manual
Page Navigation
  25    26    27    28    29  30  31    32    33    34    35  
TM 5-4220-227-14 Section III.  OPERATION UNDER USUAL CONDITIONS Paragraph Page 2-11 General .........................................................................................................................2-16 2-12 Decals and Instruction Plates.........................................................................................2-16 2-13 Startup Procedures .......................................................................................................2-16 2-14 Normal Procedures........................................................................................................2-33 2-15 Shutdown Procedures ...................................................................................................2-43 2-16 Modified Startup Procedures  ........................................................................................2-51 2-17 Modified Shutdown Procedures  ....................................................................................2-56 2-11.  General.  This section contains step-by-step instructions for preparing the 3-Person Recompression Chamber for operation.  Figure 2-5 must be used by the operator to ensure that the correct procedures are performed before, during, and after chamber operation. 2-12.  Decals and Instruction Plates.  The locations of the operating instructions or caution/warning decals and plates are illustrated in figures 2-6 through 2-9. 2-13.  Startup Procedures.  These procedures are required to prepare the chamber for operation (figure 2-10), and must be performed after a complete shutdown (para.  2-15). WARNING These  procedures  should  only  begin  after  the  primary  and  secondary  air  systems,  oxygen  banks  and heater/chiller unit are connected to the recompression chamber but not pressurized or activated Failure to do so may result in damage to the equipment and/or injury or death to personnel. The  operating  procedures  given  are  not  intended  to  be  used  as  therapeutic  procedures.  Treatment  of patients  is  not  within  the  scope  of  this  manual.    The  following  instructions  and  procedures  are  intended only to show the mechanical operation of the recompression chamber, complete information on operation is to be provided by the proper authorities. It is mandatory that these operating procedures be followed in the sequence given. Failure to do so may result in damage to the equipment and/or injury or death to personnel. CAUTION Hearing Protection is required when checking air system. NOTE The  primary  air  system  is  used  to  attain  treatment  depth  and  maintain  the  chamber  at  the  desired  flow rate.    The  primary  air  system  is  used  with  the  secondary  air  system  to  rapidly  Increase  or  decrease chamber air pressure. 2-16







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.