Table 4-1. Maintenance and Operating Supplies
Section Il. MOVEMENT TO A NEW WORK SITE

TM-5-4310-277-14 Compressor Reciprocating Air 15 CFM 175 PSI Tank Mounted GED (Champion Pneumatic Model HGR5-8M-1) Manual
Page Navigation
  36    37    38    39    40  41  42    43    44    45    46  
TM 5-4310-277-14
Figure 4-4. Mounting base plan, model HGR5-8M-1, and HGR5-8M-6.
installed within a building or vehicle, pipe the
(2) Location. If possible avoid muddy, sandy,
exhaust to the outside. Use as few bends as possible
or dusty location as a site for installation as dirt and
moisture shorten the life of all moving parts.
in the exhaust line and make sure all connections are
tight.
(3) Leveling. The air compressor should be as
level as possible when installed or set up for use.
(5) Noise hazard warning signs. Signs con-
forming to provisions of AR 385-30 will be erected in
When operating in an enclosed area, pipe
the area to provide notification of NOISE HAZARD
in accordance with TB MED-251. The signs should
exhaust gases to the outside by extending
exhaust pipe. The exhaust gases contain
read:
carbon monoxide, a colorless and odorless
poisonous gas. Inhalation of exhaust fumes
Noise
Hazard
Equipment
Hearing
Protection Required.
will result in serious illness or death.
(4) Installation. If the compressor is to be
Change 1