Section VII. MAINTENANCE OF THROTTLE CONTROL
Section Vlll. MAINTENANCE OF EXHAUST SYSTEM

TM-5-4310-277-14 Compressor Reciprocating Air 15 CFM 175 PSI Tank Mounted GED (Champion Pneumatic Model HGR5-8M-1) Manual
Page Navigation
  51    52    53    54    55  56  57    58    59    60    61  
TM 5-4310-277-14
Figure 4-11. Manifolds, valves, tubes and fittings, exploded view.
b. Cleaning and Inspection.
open flame or excessive heat. Flash point of
solvent is 100 F. (38C.) - 138 F. (59 C.).
(1) Clean all parts in cleaning solvent, Federal
Dry cleaning solvent, P-D-680, used to clean
Specification P-D-680, and dry thoroughly.
parts is potentially dangerous to personnel
(2) Inspect all parts for cracks, breaks, dents,
and  property.  Avoid  repeated  and
prolonged skin contact. Do not use near
4-21