Figure 4-27.1. Check valve, exploded view.
Oil Level Gage - TM-5-4310-277-140108

TM-5-4310-277-14 Compressor Reciprocating Air 15 CFM 175 PSI Tank Mounted GED (Champion Pneumatic Model HGR5-8M-1) Manual
Page Navigation
  82    83    84    85    86  87  88    89    90    91    92  
TM 5-4310-277-14
Figure 4-28. Globe valve, exploded view,
b. Cleaning and Inspection.
Clean all parts with cleaning solvent, Federal
Specification P-D-680, and dry thoroughly. Inspect
Dry cleaning solvent, P-D-680, used to clean
parts for cracks, dents, breaks, or other damage.
parts is potentially dangerous to personnel
Replace defective parts.
and property.  Avoid repeated and
c. Assembly and Installation.
prolonged skin contact. Do not use near
(1) Assemble globe valve by installing screw (9,
open flame or excessive heat. Flash point of
fig. 4-28), washer (8), stem (7), washer (6), packing
solvent  is  100F.  (38C.)  -  138F.
(5), bonnet (4) and nut (3) to body (10).
(59oC.).