TM 5-4310-362-14
MOTOR STARTER (cont)
LOCATION/ITEM
ACTION
REMARKS
6-9. INSTALLATION
WARNING
Voltages present in this
equipment can cause in-
jury or death.
Make sure main power is
disconnected before
doing any work on elec-
trical systems.
1.
Starter mounting bracket
Attach with 2 screws (2), wash-
ers, lockwashers and nuts.
2.
Starter enclosure (3)
Attach to bracket (1) with 4
screws (4), washers, lockwashers
and nuts.
3.
Conduits (5) and wires
Attach to enclosure with con-
duit nut (6).
4.
Starter (7)
Mount in enclosure with 2
screws (8).
If unsure of how to wire the starter, see
the diagram below
5.
Wires (9)
Attach to starter terminals per
tags.
6.
Door (10)
Close
7.
Drain cock on bottom of
a.
Open
air tank
b.
Close when pressure is below
100 psi.
STARTER EXTERNAL WIRING
NOTE V and W are coil terminals on
Top of starter. All other terminals are
on Front of starter.
8.
Main power
Connect
Motor should start up. If not, discon-
nect power and recheck wiring.
6-12