TM 5-4310-370-14
TABLE 4-1. ORGANIZATIONAL TROUBLESHOOTING (Cont'd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Adjust as described in Chapter 3, Section III,
paragraph 3-4.
Step 3.
Check level of oil to see if it is low.
If oil level is low, fill to correct level as described
in Chapter 3, Section I, paragraph 3-1.
Step 4.
Check oil to make sure correct weight oil is being used.
If improper oil weight is found, change oil as described
in Chapter 3, Section I, para graph 3-1.
Section III. MAINTENANCE PROCEDURES
4-5. V BELT REPLACEMENT.
WARNING
Disconnect compressor unit from main power supply before servicing, replacing
or repairing parts of equipment, to avoid personal injury.
a. Loosen belt guard fasteners . (Figure 4-2)
b. Remove belt guard front. (Figure 4-2)
c. Loosen motor mounting nuts and move motor towards compressor pump until V belts can be removed easily.
(Figure 4-2)
d. Remove old V belts and replace with new set (both V belts must be replaced).
e. Move motor away from compressor pump, tightening V belts (figure 4-2). Play in fully tightened V belts should be
no more than 1/2".
f. Tighten motor mounting nuts.
g. Install belt guard front. (Figure 4-2)
h. Tighten belt guard fasteners. (Figure 4-2)