REMOVAL AND REPLACEMENT OF PRESSURE GAGE. - TM-5-4310-370-140042
GLOBE VALVE REPLACEMENT.

TM-5-4310-370-14 Compressor Unit Reciprocating Electric 5 CFM 175 PSI (4310-01-089-4330) Manual
Page Navigation
  32    33    34    35    36  37  38    39    40    41    42  
TM 5-4310-370-14
TM 5-4310-370-14/4-8
FIGURE 4-8. PRESSURE GAGE REMOVAL AND REPLACEMENT
4-11. CHECK VALVE REPLACEMENT.
WARNING
Disconnect compressor unit from main power supply before servicing, replacing
or repairing parts of equipment, to avoid personal injury.
WARNING
Release pressure from air receiver and compressor pump before inspection,
performing procedures, or disassembly of equipment to avoid personal injury.
a. Turn compression nut counter clockwise until disconnected from check valve (figure 4-9).
b. Remove check va lve by turning counter clockwise until disconnected from air receiver (figure 4-9).