TM   5-4310-372-14 2-15 e .    D r a i n    F u e l    S t r a i n er 1. 2. 3. 4. L o o s en the nut (1) at the bottom of the fuel strainer   bowl   (cradle   assembly). Swing   the   cradle   (2)   to   one   side   and   carefully   lower the   bowl   (3). Remove   gasket   (4)   and   strainer   (5). Empty   the   bowl   and   discard   gasket. Install   strainer   (5)   in   upper   housing   (6)   then   place new   gasket   (4)   and   bowl   (3)   over   strainer. Swing   cup   of   cradle   assembly   (2)   beneath   bowl   and secure   with   nut   (1)   at   base. f . Secure   the   air   hose   assembly   to   the   air   receiver   tank. g . L i f t     t h e     a i r     c o m p r e s s o r     a n d     a c c e s s o r i e s     o n     a     s u i t a b le carrier   and   block   and   tie   it   down. h. Move   the   air   compressor   to   a   new   worksite   or   storage. i . R e f e r     t o     p a r a g r a p h     2 - 4     f o r     p l a c i n g     u n i t     b a c k     i n to s e r v i c e .