TM   5-4310-372-14 3-11.   AIR   RECEIVER   TANK. a.   Open   draincock   (1)   daily   to   remove   moisture   from   the a i r    r e c e i v e r    t a n k . b. Keep   all   fittings   connected   to   the   air   receiver   tank t i g h t. Check   for   leaks   with   soapy   water   with   pressure in   air   receiver   tank. 3 - 1 2 . AIR  DISCHARGE  SYSTEM. a . Examine   shut-off   valve   (2)   for   cracks   or   leaks. b . Examine   fittings   for   leaks. Check   with   soapy   water. c . Examine   hoses   (3)   for   cracks   or   leaks. d. Examine   inflator   gauge   (4)   for   cracked   dial   glass, s t r i p p e d    t h r e a d s, leaks,   or   defective   handle. 3-11