b. Unpacking and deprocessing. Remove all crating, blocking, and protective material. Refer to DA Form 2258
(Depreservation Guide for Vehicles and Equipment) furnished with the unit and complete reprocessing as necessary
before doing any servicing.
(1) Refer to Components of End Items List (Appendix C) and check to see if you have received all required items.
(2) Refer to Additional Authorization List (Appendix D) and check to see if you have received additional items
authorized for support of the air compressor.
(3) Check for and tighten any loose mounting screws and nuts. Visually check for missing parts and for damage
that may have occurred during shipment.
(4) Position unit where there is adequate ventilation and air circulation for cooling. Installation must be at least
2 feet (0.6 meters) from wall to belt guard.
(5) Secure unit to floor, when required. Refer to figure 2-2 for mounting diagram.
Figure 2-2. Unit floor mounting diagram.