  21    22    23    24    25  26  27    28    29    30    31  
TM 5-4310-375-14
Table 3-2. Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. COMPRESSOR RUNNING TOO HOT - Continued
WARNING
When cleaning with compressed air, nozzle pressure shall not exceed
30 psi (2.11 kgs/cm2). Eye protection is required.
Use compressed air to blow off any accumulation of dust or dirt.
6. COMPRESSOR RUNNING TOO SLOW
WARNING
Electricity is dangerous. Before performing any maintenance or adjustments,
be sure the electrical power is turned off. Never depend on the ON-OFF switch.
Turn power off at the source.
Turn power off at the source and check for loose wiring connection. Also, check that main power source is
230 volts, 3 phase, 60 hertz.
Notify Organizational Maintenance.
Section III. MAINTENANCE PROCEDURES
Introduction. This section contains those maintenance tasks authorized by the Maintenance Allocation Chart
3-5.
(Appendix B) for operator/crew level. Maintenance for higher levels will be found in later Chapters.
3-6.
Belt guard assembly.
a. Inspection. Inspect belt guard assembly (fig 3-3) for damage to the screen or panels. Inspect for accumulation of
grease, dirt, or foreign matter.
WARNING
Dry cleaning solvent, Fed Spec P-D-680, used to clean parts is potentially
dangerous to personnel and property. Avoid repeated and prolonged skin
contact. Do not use near open flame or excessive heat. Flash point of
solvent is 100F - 138F (38C - 59C).
b. Cleaning. Clean the belt guard with a rag dipped in solvent, P-D-680, or equivalent, and dry thoroughly.