ENGINE DOES NOT STOP WHEN STOP SWITCH IS TURNED OFF
Engine Air Cleaner - TM-5-4310-376-140048

TM-5-4310-376-14 Compressor Reciprocating Gasoline Engine Driven 15 CFM 175 PSI Model 50-6840 Manual
Page Navigation
  23    24    25    26    27  28  29    30    31    32    33  
TM 5-4310-376-14
SERVICING - Continued
3-6.
For maximum removal of impurities, drain
only when frame oil is warm.
(a) Remove oil drain plug (2).
(b) Oil is drained when it stops running out.
(c) Replace oil drain plug and tighten.
(d) See lubrication chart for proper grade of oil.
(e) Replace oil filler plug (1). FINGER TIGHT ONLY.
b. Compressor Air Cleaner
(a) Wipe off outside and mouth of body (1).
(b) Remove disc (2) by turning counter clockwise.
(c) Remove three pads (3).
(d) Remove remaining disc (4).
Dry cleaning solvent P-D-680 (safety or Stoddard's Sol-
vent) is potentially dangerous. Avoid repeated and pro-
longed breathing of vapors and skin contact with the
liquid. Do not use near open flame, arcing equipment or
other ignition sources. Always wear eye protection and
protective clothing. The flash point of P-D-680 is 100
to 138F (30 to 59C).
(e) Wash inside of filter body and wipe dry.
(f) Inspect pads for excessive wear or loss of capacity to re-
tain dust or dirt.
(g) Wash pads and disc and blow dry with low compressed air.
(h) Position one disc in body.
(i) Stack three pads in body.
(j) Secure pads in body with remaining disc.