AIR CLEANER. - TM-5-4310-377-130064
Figure 3-22. Air Cleaner, Installation.

TM-5-4310-377-13 Compressor Unit Reciprocating 5 CFM 175 PSI Electric Motor Driven Model:E23CV7A Manual
Page Navigation
  54    55    56    57    58  59  60    61    62    63    64  
TM 5-4310-377-13
3-18. AIR CLEANER - Continued.
a. Removal. (Refer to Figure 3-21).
Figure 3-21. Air Cleaner, Removal.
(1) Remove wing nut (1), washer (2), and cover (3).
(2) Remove filter (4) and screen (5).
(3) Remove air cleaner body (6).
b. Cleaning.
(1) Remove all buildup of dirt, grease, etc. by wiping with a soft cloth (Appendix E, item 3).
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable.  Use
solvent only in a well-ventilated area. Avoid prolonged breathing of fumes. Keep
solvent away from flames. Do not use in excessive amounts. Avoid skin contact.
(2)  Clean using a clean, soft cloth (Appendix E, item 3) or a medium bristle brush (Appendix E, item 4) and
cleaning solvent (Appendix E, item 2).
(3) Allow to dry.