3-26. DRAIN COCK.
This task covers:
a. Removal
b. Cleaning
c. Inspection
d. Replace
e. Installation
SET-UP:
Tools:
9/16 inch Wrench
Materials:
Brush, Medium Bristle (Appendix E, item 4)
Cloth, Lint-Free (Appendix E, item 3)
Solvent, Dry Cleaning (Appendix E, item 2)
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable.  Use
solvent only in a well-ventilated area. Avoid prolonged breathing of fumes. Keep
solvent away from flames. Do not use in excessive amounts. Avoid skin contact.
Personnel:
1 Person
Equipment Conditions: Electrical power removed at master control panel.
Tank drain cock open and air bleed off (para. 2-2).
a. Removal. Unscrew and remove drain cock (1, Figure 3-39).
Figure 3-39. Drain Cock, Removal.