Cleaning  Method  -Trisodium  Phosphate  (TSP ).

TM-5-4310-379-14 Compressor Air Reciprocating Electric Motor Driven Reciprocating Electric Motor Driven 15 CFM at 175 PSI Manual
Page Navigation
  203    204    205    206    207  208  209    210    211    212    213  
TM 5-4310-379-14 a.   Cleaning Components or Assemblies (excluding hose assemblies). CAUTION Chemical protective gloves should be worn to prevent skin irritation from detergent and hot water. (1) Disassemble components down to the smallest parts.  Separate soft goods and clean as specified in paragraph 3-61. (2) Clean each component by scrubbing with a non-ionic detergent solution (1/2 teaspoon (2.4 mL) detergent to 1 gallon (3.8 I) water) using a nylon bristle brush and clean cloths. (3) Rinse with distilled water at 125 degrees F (54 degrees C) until effluent shows no visible signs of detergent. (4) Collect some of the water rinsed over the items in a flask that can be fitted with a rubber stopper.  Shake the flask for a few seconds and if any bubbles form and remain on the surface of the water in the flask, continue to rinse item until no bubbles form and remain in the sample flask. (5) Purge  with  dry,  oil-free  nitrogen  until  visually  dry,  or  allow  to  air  dry.    The  following  dated  and  signed  records shall be maintained: (a) Identification of all parts cleaned. (b) Results of shake test. (6) Reassemble as outlined on assembly or component drawing. (7)  Double bag all components in plastic and close securely. b.  Cleaning Hose Assemblies. (1) Clean  hose  assemblies  in  accordance  with  the  following  steps  using  the  specific  materials  and  utilizing  proper equipment.  Pre-clean hose assemblies outside the clean area by rinsing externally with distilled water. (2) Most  hose  assemblies  will  not  lend  themselves  to  disassembly.    Disassemble  to  maximum  extent  without removing fittings or clamps. (3) The cleaning solution shall be made by adding 1/2 ounce (14.7 mL) non-ionic detergent to each 80 gallons (302.8 11) of distilled water. (4) Heat  the  cleaning  solution  to  120  degrees  F  (49  degrees  C)  and  circulate  through  the  hose  assembly  for  30 minutes at a flow rate of not less than 1 gallon (3.8 I) per minute. (5) Rinse the hose assembly with distilled water heated to 125 degrees F (52 degrees C) for 30 minutes minimum at a flow rate of not less than 1 gallon (3.8 I) per minute.  Do not recirculate the water. 3-183







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.