  30    31    32    33    34  35  36    37    38    39    40  
TM 5-4310-379-14 Table 3-2.  Unit Troubleshooting Procedures (Cont). MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 2. ENGINE RUNS ROUGH OR ERRATICALLY. Step 1. Air cleaner dirty. Service air cleaner (para. 3-28). Step 2. Altemator defective. Replace a damaged alternator (para. 3-33). Step 3. Fuel filter dirty. Service fuel filter (para. 3-25). Step 4. Fuel strainer dirty. Service fuel strainer (para. 3-26). 3. ENGINE OVERHEATS. Step 1. Coolant level flow. Add coolant as needed. Step 2. Water connections damaged. Replace a dented or damaged water connection (para 3-20). Step 3. Crankcase oil low. Check oil level and add oil as needed. Step 4. Alternator fan belts loose. Tighten fan belts (para. 3-33) Step 5. Water pump defective. Replace water pump (para. 3-23). 3-10