Table 2-1. Operator Preventive Maintenance Checks and Services - Continued - TM-5-4310-380-130022
Section III. OPERATION UNDER USUAL CONDITIONS - TM-5-4310-380-130024

TM-5-4310-380-13 Compressor Unit Reciprocating 15 CFM 175 PSI Electric Motor Driven Model:10HT8G Manual
Page Navigation
  11    12    13    14    15  16  17    18    19    20    21  
TM 5-4310-380-13
Table 2-1. Operator Preventive Maintenance Checks and Services - Continued
B - Before
D - During
A - After
INTERVAL
ITEM
ITEM TO BE INSPECTED
EQUIPMENT IS NOT READY,
NO.
B
D
A
PROCEDURE
AVAILABLE IF:
14
Drain Cock
Damaged.
Open the drain cock (1) and
allow all condensed moisture
to drain off. Close the
drain cock.
15
Air Shut Off Valve.
Open valve will not
Check that air is released
release air from air
when valve is open.
tank or leaks.
16
Air Tank.
Check for secure mounting,
Damage or leaks.
damage and leaks.
17
Hose.
Damage or leaks.
Inspect for damage and air
leaks.
18
Inflator Gage.
Leaks or missing.
Check for leaks and damage.
2-9