TM 5-4310-380-13
3-22. SAFETY VALVE.
This task covers:
a. Removal
b.  Cleaning
c.
Inspection
d. Replace e.
Installation
SET-UP:
Tools:
11/16 inch wrench
Materials:
Brush, Medium Bristle (Appendix E, item 4)
Cloth, Lint-Free (Appendix E, item 3)
Solvent, Dry Cleaning (Appendix E, item 2)
Tape, Teflon (Appendix E, item 8)
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable. Use solvent only in a
well ventilated area. Avoid prolonged breathing of fumes. Keep solvent away from flames.
Do not use in excessive amounts. Avoid skin contact.
Personnel:
1 Person
Equipment Conditions:
Electrical power removed at master control panel.
Tank drain cock open and air bled off (para. 2-4) .
a. Removal. Unscrew and remove the safety valve (1, Figure 3-29).
Figure 3-29. Safety Valve, Removal.
GO TO NEXT PAGE