Cleaning. - TM-5-4310-380-130081
Figure 3-31. Check Valve, Removal.

TM-5-4310-380-13 Compressor Unit Reciprocating 15 CFM 175 PSI Electric Motor Driven Model:10HT8G Manual
Page Navigation
  70    71    72    73    74  75  76    77    78    79    80  
TM 5-4310-380-13
3-22. SAFETY VALVE - Continued.
e. Installation. Install the safety valve (1, Figure 3-30).
NOTE
Wrap thread with teflon tape (Appendix E, item 8).
Figure 3-30. Safety Valve, Installation.
END OF TASK
3-23. CHECK VALVE.
This task covers:
a. Removal
b.
Cleaning
c.
Inspection
d. Replace
e.
Installation
SET-UP:
Tools: 1 5/16 inch wrench
36 mm wrench
1/2 inch wrench
1 1/8 inch wrench
Materials:
Brush, Medium Bristle (Appendix E, item 4)
Cloth, Lint-Free (Appendix E, item 3)
Solvent, Dry Cleaning (Appendix E, item 2)
Compound, Piping (Appendix E, item 7)
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable. Use solvent only in a
well ventilated area. Avoid prolonged breathing of fumes. Keep solvent away from flames.
Do not use in excessive amounts. Avoid skin contact.
GO TO NEXT PAGE