Figure 3-31. Check Valve, Removal.
PRESSURE GAGE. - TM-5-4310-380-130085

TM-5-4310-380-13 Compressor Unit Reciprocating 15 CFM 175 PSI Electric Motor Driven Model:10HT8G Manual
Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
TM 5-4310-380-13
3-23. CHECK VALVE - Continued.
b. Cleaning - Continued.
(2) Clean using a clean, soft cloth (Appendix E, item 3) or a medium bristle brush (Appendix E, item 4) and
cleaning solvent (Appendix E, item 2).
(3) Allow to dry.
c. Inspection.
(1) Inspect for stripped threads.
(2) Inspect for signs of obvious damage.
d. Repair. Replace a defective check valve.
e. Installation. (Refer to Figure 3-32).
NOTE
Apply piping compound (Appendix E, item 7) on all threads.
Figure 3-32. Check Valve, Installation.
(1) Install check valve (5).
(2) Install elbow (4).
(3) Install compression fitting (3).
(4) Connect pressure switch unloader tube (2).
(5) Connect input tube (1) from compressor.
END OF TASK
3-57