TM 5-4310-380-13
3-24. PRESSURE GAGE - Continued.
b. Cleaning.
(1) Remove all buildup of dirt, grease, etc. by wiping with a soft cloth (Appendix E, item 3).
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable. Use solvent only in
a well-ventilated area. Avoid prolonged breathing of fumes. Keep solvent away from flames.
Do not use in excessive amounts. Avoid skin contact.
(2) Clean using a clean, soft cloth (Appendix E, item 3) or a medium bristle brush (Appendix E, item 4) and
cleaning solvent (Appendix E, item 2).
(3) Allow to dry.
c Inspection
(1) Inspect for stripped threads.
(2) Inspect for signs of obvious damage.
d. Repair. Replace a defective pressure gage.
e. Installation. Install the pressure gage (1, Figure 3-34).
NOTE
Wrap thread with teflon tape (Appendix E, item 8).
Figure 3-34. Pressure Gage, Installation.
END OF TASK