TM 5-4310-384-13 SECTION VII.  PREPARATION FOR STORAGE 3-46. LONG TERM STORAGE.  For storage longer than 30 days, prepare the air compressor as follows: WARNING Disconnect main power and turn compressor unit off before performing maintenance procedures. a. Turn compressor switch (1) OFF. b. Remove oil drain cap (2) and drain oil into suitable container.  Replace cap. c. Refill crankcase with 16 oz.  (.5 L) of 30 weight preservative lubricating oil (MIL-L-21260B, Grade 2). d. Open the drain cock (3) to release air pressure in tank. e. Remove  the  belt  guard  cover  (paragraph  3-23)  and  loosen  belt  tension  (paragraph  3-24).    Insert  heavy  paper strips between the pulleys and belts to prevent sticking. f. Clean and dry the compressor unit with a wiping rag. g. Protect  the  compressor  with  a  good  weather-resistant  tarpaulin  and  store  it  under  cover,  preferably  in  a  dry building. 3-72