TM 5-4310-384-13 Table  3-2.  Unit Preventive Maintenance Checks and Services (Continued). W - Weekly M - Monthly Q - Quarterly Semi-Annually Item Interval No. W M Q S Item to Be Inspected.  Procedures WARNING Extreme caution must be exercised when circuits have been energized. Contact with line circuits can cause severe personal injury or death. c.   With power on and ON/OFF switch on, observe motor starter while compressor cycles.  Magnetic contact arm (3) should open and Close (contact base) with operation of pressure switch. d.   Check mounting of thermostat and check capillary tube and leads to regulator/filter for secure mounting. 2 PRESSURE SWITCH a.   Inspect pressure switch fitting (1) at tank for air leaks. b.   Turn power off and ON/OFF switch off.  Check wire connections at screw terminals (2) for secure attachment. c.   With power on and ON/OFF switch on, check operation of pressure switch (3) by observing pressure gage on air receiver. Pressure switch should engage starter at 160 psi and stop starter at 190 psi. 3-6