• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Operating Procedure - TM-5-4310-385-13_25
CHAPTER 3.  UNIT MAINTENANCE INSTRUCTIONS - TM-5-4310-385-13_27

TM-5-4310-385-13 Compressor Reciprocating Air: Electric Motor Driven Caster Mounted 5 CFM 175 PSI C & H Model 20-917 Manual
Page Navigation
  15    16    17    18    19  20  21    22    23    24    25  
TM 5-4310-385-13 SECTION IV.  OPERATION UNDER UNUSUAL CONDITIONS 2-10.  OPERATION IN DUSTY ENVIRONMENT a. Check and clean air filter (1) and silencer (2) daily to keep it from being clogged. b. Clean  dirt  off  of  electric  motor  (3),  compressor  fins  (4),  intercooler  tubing  (5),  and  aftercooler   tubing   (6)   to maximize air cooling ability. 2-11.  OPERATION IN EXTREME HEAT. a. Make sure that there are no air flow obstructions through the slotted belt guard to the fan bladed flywheel. b. Clean dirt off of electric motor (3), compressor fins (4), intercooler tubing (5), and aftercooler tubing (6) to maximize air cooling ability. c. Check air filter (1) and silencer (2) in accordance with the PMCS table schedule (weekly) or sooner (daily). d. Check for proper oil viscosity.  Refer to paragraph 3-2. Operation Under Unusual Conditions 2-11 (2-12/Blank)







Western Governors University