3-24.  V-BELT.
3-25.  DRIVE PULLEY

TM-5-4310-385-13 Compressor Reciprocating Air: Electric Motor Driven Caster Mounted 5 CFM 175 PSI C & H Model 20-917 Manual
Page Navigation
  38    39    40    41    42  43  44    45    46    47    48  
TM 5-4310-385-13 INSTALLATION. a. Disconnect the main power source and turn the power switch OFF. b. Be sure the electric motor mounting bolts (1) are loose and motor is moved toward compressor flywheel. NOTE V-belts must be replaced as a set. c. Place V-belts (2) in position over compressor flywheel (3) and drive pulley (4). d. Adjust belt tension.  Refer to next paragraph. V-Belt Adjustment ADJUSTMENT. WARNING Disconnect  main  power  source  and  turn  compressor  unit  off  before  performing maintenance procedures. a. Disconnect main power supply and turn power switch OFF. b. Remove belt guard.  Refer to paragraph 3-23. c. Loosen  the  electric  motor  mounting  bolts  (1)  and  slide  motor  away  from  compressor  to  tighten  belt  tension  or towards compressor to loosen. CAUTION Too  little  belt  tension  causes  belts  to  overheat  and  wear  out  prematurely.    Too much tension causes bearing wear in motor and compressor. d. Tighten  mounting  bolts  (1)  when  proper  belt  tension  is  achieved.    Belt  should  move  1/2"  when  pushed  halfway between pulley (4) and flywheel (3). e. Install belt guard.  Refer to paragraph 3-23. 3-23