• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
INSTALLATION. - TM-5-4310-385-13_63
Short Circuit Test

TM-5-4310-385-13 Compressor Reciprocating Air: Electric Motor Driven Caster Mounted 5 CFM 175 PSI C & H Model 20-917 Manual
Page Navigation
  53    54    55    56    57  58  59    60    61    62    63  
TM 5-4310-385-13 3-33.  ELECTRIC MOTOR.  This task covers: a.  Initial Setup. c.  Short Circuit Test. e.  Installation. b.  Continuity Test. d.  Removal. INITIAL SETUP. a. Tools.  General Mechanic Automotive Tool Kit T1 5180-00-177-7033; Automotive Maintenance and Repair Shop Equipment, T3 4910-00-754-0654. b. Equipment Condition.  Main power disconnected; Compressor unit OFF; Belt guard removed (paragraph 3-23) ; V-Belts removed (paragraph 3-24) ; Drive pulley removed (paragraph 3-25). c. General Safety Requirements. WARNING · Observe all Warnings and Cautions. · Never wear loose clothing or jewelry while inspecting or servicing equipment. · Beware of rotating shafts, pulleys and fans which could entrap personnel and cause serious injury. SET MULTIMETER TO OHMS x 1 SCALE Continuity Test CONTINUITY TEST. WARNING Disconnect    main    power    and    turn    compressor    unit    off    before    performing maintenance services. a. Disconnect main power and turn compressor switch OFF. b. Tag and disconnect motor leads (T1, T2, T3). c. Set multimeter to OHMS x 1 scale. 3-38







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.