• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Short Circuit Test
INSTALLATION - TM-5-4310-385-13_67

TM-5-4310-385-13 Compressor Reciprocating Air: Electric Motor Driven Caster Mounted 5 CFM 175 PSI C & H Model 20-917 Manual
Page Navigation
  55    56    57    58    59  60  61    62    63    64    65  
TM 5-4310-385-13 Electric Motor REMOVAL. a. Disconnect main power and turn compressor switch OFF. b. Remove the belt guard (1).  Refer to paragraph 3-23. c. Loosen four mounting bolts, washers, nuts (2). d. Slide motor (3) towards compressor unit and remove V-belts (4). e. Remove drive pulley (5).  Refer to paragraph 3-25. f. Remove screws (6) and cover plate (7) on motor conduit box (8). g. Tag and disconnect motor leads (T1, T2, T3) in conduit box. h. Remove conduit locknut and remove conduit (9) and wires (10) from box (8). i. Remove four mounting bolts, washers, and nuts (2). j. Lift electric motor (3) off tank saddle. 3-40







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.