TM 5-4310-385-13 REMOVAL. a. Turn compressor switch OFF. WARNING Shutoff valve must be closed or air in tank must be discharged before removal of hoses.  Removal under pressure could cause serious injury. b. Turn shutoff valve (1) clockwise to close air supply. WARNING Air in hoses must be discharged before removing hose. c. Depress lever (2) to discharge any air pressure in hoses (3). d. Remove hoses at shutoff valve fitting (4) and inflator gage fittings (5). INSTALLATION. a. Install hoses (3) at shutoff valve fitting (4) and inflator gage fittings (5).  Tighten fittings. b. Turn shutoff valve (1) counterclockwise to open air supply. c. Turn compressor unit ON, run compressor, and check for leaks. 3-56