5.  SIGHT GLASS EXHIBITS AIR BUBBLES
11.  SAFETY VALVES BETWEEN STAGES RELEASING PRESSURE

TM-5-4310-386-14 Compressor Reciprocating Air: Electric Motor Driven & CFM 175 PSI C & H Model 20-918 Manual
Page Navigation
  203    204    205    206    207  208  209    210    211    212    213  
TM 5-4310-386-14 Table 5-1.  Direct Support Troubleshooting Procedures (Cont). MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 8.  CONDENSATE AUTOMATIC DRAIN NOT DRAINING (COLD WEATHER). Interfilter heater block inoperative. Replace element if necessary (para.  5-15). 9.  NO COMPRESSOR OIL PRESSURE. Step 1.  Check oil supply lines. Tighten or replace oil supply lines as needed (para.  5-11). Step 2.  Check compressor oil pump. Replace compressor oil pump (para.  5-11). Step 3.  Check oil pressure regulator. Adjust or replace oil pressure regulator (para.  5-12). 10.  COMPRESSOR OUTPUT INSUFFICIENT. Step 1.  Check engine rpm. Adjust as required. Step 2.  Check interfilter safety valves. Replace interfilter safety valves if damaged (para.  5-16). Step 3.  Check interfilter drain valves. Replace or repair interfilter drain valves (para.  5-17). Step 4.  Check first stage safety valve. Replace first stage safety valve if damaged (para.  5-14). Step 5.  Check fourth stage safety valve. Replace fourth stage safety valve if damaged (para.  5-24). 5-5