TM-5-4310-389-14 SERVICE a. Removal (figure 4-71). 1. Using Securus wrench, unscrew chamber caps (9). 2. Remove and discard filter (7). b. Installation. CAUTION While   replacing   filters,   do   not   allow   hands   to   come   in   contact   with   filters.      Follow   installation instructions explicitly. 1. Remove both ends of filter packaging. 2. Remove protection caps at either end. 3. Grasp filter in mid-section with filter packaging in place. 4. Position filter over housing and carefully allow filter to slide  fiom packaging into housing.  Press down on filter to seat 0-rings. 5. Reinstall cap and, using Securus wrench, tighten cap securely. REPLACE REPAIR a. Removal. 1. Remove inlet tubing from the pressure maintaining valve (PMV). 2. Remove the final gauge line from the bleed down tee fitting. 3. Remove the PMV. 4. Remove the outlet tubing. 4-112