2-10 START-UP PROCEDURE (MANUAL).
2-11   SHUTDOWN PROCEDURE

TM-5-4310-389-14 Air Compressor 5.1 CFM Diesel Engine Driven Model KA7-DA Manual
Page Navigation
  19    20    21    22    23  24  25    26    27    28    29  
TM-5-4310-389-14 Figure 2- 6.  Decompression Device Figure 2-7.  Cranking Device b. Manual Start (Battery Dead and Alternator Not Producing Voltage). 1. Place crank bungie cord from run solenoid to muffler guard. 2. Remove condensate drain solenoid and remove the cylindrical valve from the condensate block. 3. Remove the spring from the piston and reinstall the piston into the cylindrical valve and reinstall (solenoid does not have to be reinstalled, but should be placed over the cylindrical valve to prevent damage. 4. Turn throttle two turns from the IDLE position. 5. Turn decompressor lever counterclockwise until it stops. 6. Place crank in crank hole and turn counterclockwise (engine will turn freely for approximately six turns before compression). 7. Allow warm-up, then bring to full throttle and engage clutch. CAUTION No safety devices will activate during this start-up procedure. 2-12