TM-5-4310-389-14 Air Compressor 5.1 CFM Diesel Engine Driven Model KA7-DA Manual
Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
TM-5-4310-389-14 Table 3-2.  Unit Troubleshooting Procedures (Continued) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 14. Automatic drain does not close. Step 1.  Check electrical circuit on condensate solenoid.  Check supply lines. 15. Automatic drain leaks and blows off. Step  1.    Check  to  see  if  drain  valves  are  dirty.    Remove  and  clean  valves.    Notify  Direct  Support Maintenance. 16 Compressor speed low. Step 1.  Check to see if drive belts have proper tension.  Adjust idler pulley. Step 2.  Check to see if engine is running at rated rpm.  Increase speed to correct rpm.  Notify Direct Support Maintenance. Step 3.  Check clutch for slippage.  Adjust clutch. ENGINE 17. Engine does not turn over. Step 1.  Improper starting procedure.  Follow proper starting procedure. Step 2.  Check to see if battery is defective or dead.  Recharge or replace. Step  3.    Check  to  see  if  cable  connections  of  starter  motor  circuit  are  oxidized.    Replace  cable connections. Step 4.  Check to see if cable connections of starter motor circuit are loose.  Tighten connections. Step 5.  Check to see if starter motor is defective or pinion does not engage.  Notify Direct Support Maintenance.  Replace starter motor. Step  6.    Check  to  see  if  starting  aid  is  defective.    Notify  Direct  Support  Maintenance.    Replace starting aid or ensure ether reservoir is full. 18. Engine fails to start or difficult to start. Step 1.  Improper starting procedure.  Follow proper starting procedure. 3-14







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.