TM 5-4310-451-14 5-42.  OIL PUMP ASSEMBLY MAINTENANCE (Con’t). 3.  Remove four bolts (5), lockwashers (6), oil pump assembly (2), and gasket (1).  Discard lockwashers and basket. b.  DISASSEMBLY 1. Remove   eight   locking   screws   (12)   and   cover (11) from oil pump housing (9). 2. Remove gear (13) from oil pump housing (9). 3. Remove gear (14) from shaft (15). 4. Remove shaft (15). 5. Remove plug (10) from oil pump housing (9). c.  ASSEMBLY 1. Install plug (10) on oil pump housing (9). 2. Install shaft (15). NOTE Gears must be replaced as a matched set. 3. Install gear (14) on shaft (15). 4. Install gear (13) in oil pump housing (9). 5. Aline cover (11) on oil pump housing (9) and install eight locking screws (12). TA705030 5-151