• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
INJECTOR RACK CONTROL LEVER ADJUSTMENT (Cont). - TM-5-4310-451-14_490
INJECTOR RACK CONTROL LEVER ADJUSTMENT (Cont). - TM-5-4310-451-14_492

TM-5-4310-451-14 Compressor Unit Reciprocating 5.0 CFM Model CAPITANO-PD Manual
Page Navigation
  478    479    480    481    482  483  484    485    486    487    488  
TM 5-4310-451-14 5-52.  INJECTOR RACK CONTROL LEVER ADJUSTMENT (Con’t). 10. Check for correct left-front injector rack control lever adjustment as follows: (a) While  holding  governor  control  lever  (9)  in  RUN  position,  ensure  that  injector  control  rack  (10)  is  free  to rotate slightly in a clockwise and counterclockwise direction. (b) While again holding  governor  control  lever  (9)  in  RUN  position,  press  downward  at  end  of  injector  control rack (10).  End should spring upward slightly as pressure Is released. 11. If checks performed in step 10 indicate adjustment is not correct, repeat steps 5 through 9. TA705046 5-171