5-69.  VARIABLE SPEED GOVERNOR HOUSING REPLACEMENT.
5-70.  VARIABLE SPEED GOVERNOR HOUSING REPAIR.

TM-5-4310-451-14 Compressor Unit Reciprocating 5.0 CFM Model CAPITANO-PD Manual
Page Navigation
  566    567    568    569    570  571  572    573    574    575    576  
TM 5-4310-451-14 5-69.  VARIABLE SPEED GOVERNOR HOUSING REPLACEMENT (Cont.). b.       INSTALLATION 1. Apply  grease  to  face  of  blower  assembly  (5)  and  housing  (3).    Install  new  gasket  (4)  and  housing  on  blower assembly with eight new lockwashers (2) and bolts (1). 2. Install new copper washer (6) and bolt (7) on housing (3). FOLLOW-ON TASKS: ì Install blower assembly (see paragraph 5-63). ì Install variable speed governor spring housing and linkage (see paragraph 5-68). 5-259