TM 5-4310-451-14 5-75. ENGINE STARTER REPAIR (Con’t). 40. Remove field coil (87) and plate insulator (84) from field frame (5). 41. Remove insulator bushing (86) and plate (85) from terminal stud (78). b. CLEANING AND INSPECTION WARNING Dry  cleaning  solvent,   P-D-680,   is   toxic   and   flammable.      Always   wear   protective   goggles   and gloves, and use only in a well-ventilated area.  Avoid contact with skin, eyes, and clothes, and DO NOT breathe vapors.  DO NOT use near open flame or excessive heat.  The solvent’s flash point Is 100°F-1380F (380C-590C).  If you become dizzy while using cleaning solvent, Immediately get fresh air and medical help.  If solvent contacts eyes, immediately wash your eyes and get medical aid. 1. Clean all metal parts, except armature, field coil, and starter drive, with dry cleaning solvent. 2. Clean starter drive with clean dry cloth. 3. Inspect field frame for cracks, breaks, and other obvious damage. 4. Inspect armature shaft for rough surfaces and damaged splines. 5. Inspect commutator contact surface for rough surface, pits, scoring, bums, hard carbon, oil coat, and out-of-round. Commutator diameter, when new, is 2.3125-2.3250 in.  (58.7375-59.0550 mm).  Commutator diameter may not be less than 2.0 in.  (50.8 mm) when returned to service.  Commutator may not be more than 0.002 in.  (0.051 mm) out-of-round. TA705182 5-316







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.