a. REMOVAL - TM-5-4310-452-14_104
4-23.  FUEL TANK MAINTENANCE

TM-5-4310-452-14 Compressor Air: Rotary Screw 750 CFM 100 PSI Wheel-Mounted DED SULLIAR Model 750 DP Manual
Page Navigation
  92    93    94    95    96  97  98    99    100    101    102  
TM 5-4310-452-14 4-22.  METERING FUEL PUMP MAINTENANCE (CON'T). 4.    Inspect strainer (16) for cracks or breaks. Re- place strainer if damaged. c. ASSEMBLY 1. Position strainer (16), new preformed packing (15), and cover (14) on metering fuel pump (3). 2. Install capscrew (12) and washer (13) in meter- ing fuel pump (3). d. INSTALLATION 1. Position new gasket (2) and metering fuel pump (3) on injection pump drive assembly (1). Install 3 nuts (10) and new lockwashers (11). NOTE Fluid     passage     bolt     includes     an internal check valve. 2. Position 2 hoses (9) on metering fuel pump 3).   Install 3 washers (7) and fluid passage bolt (8) in metering fuel pump. 3. Position 2 hoses (6) on metering fuel pump (3). Install 3 washers (4) and fluid passage bolt (5) in metering fuel pump. FOLLOW-ON TASKS: • Bleed fuel system (see paragraph 4-21). • Start unit and check for leaks (see paragraph 2-12). • Close left door assembly. TA505440 4-41