FOLLOW-ON TASKS - TM-5-4310-452-14_126
c. INSTALLATION - TM-5-4310-452-14_128

TM-5-4310-452-14 Compressor Air: Rotary Screw 750 CFM 100 PSI Wheel-Mounted DED SULLIAR Model 750 DP Manual
Page Navigation
  114    115    116    117    118  119  120    121    122    123    124  
TM 5-4310-452-14 4-34.  COWLING, DUCT, GUIDE RAIL, SHIELD, AND PLATE REPLACEMENT. This Task Covers: a.  Removal c.  Installation b.  Cleaning Initial Setup: Equipment Conditions: Materials/Parts: • Engine off. •·Twenty-two lockwashers • Left door assembly open. • Battery cables disconnected (see paragraph Personnel Required: Two 4-57). • Blower assembly removed (see paragraph 4-32). General Safety Instructions: • Fuel lines removed (see paragraph 4-24). • Compressed air used for drying or cleaning purposes must not exceed 30 psi (207 kPa). Tools/Test Equipment: • General mechanic's tool kit • Face mask •·Soft bristle brush a. REMOVAL 1. Open 2 fasteners (4) and remove duct (5) from guide rail (6). 2. Remove 8 bolts (7) and lockwashers (8) from guide rail (6).  Remove guide rail.  Discard lockwashers. 3. Remove 4 bolts (20), lockwashers (21), and flatwashers (22) from stay plate (37), plate (16), and shield (9).  Discard lockwashers. 4.  Remove 3 bolts (12), lockwashers (11), and flatwashers (10) from shield (9).  Remove shield.  Discard lockwashers. 5.  Remove 3 bolts (13, 19, and 29), lockwashers (14, 18, and 28), flatwashers (15, 17, and 27), and nut (23) from plate (16).  Remove plate.  Discard lockwashers. 6.    Remove  2  bolts  (30  and  40),  lockwashers  (32  and  39),  flatwashers  (33  and  38),  and  nut  (34)  from  stay  plate  (37). Discard lockwashers. 7. Remove bolt (3), lockwasher (2), washer (1), from stay plate (37).  Discard lockwasher. 8. Remove bolt (36) and washer (35) from stay plate (37). 9. Remove bolt (26), lockwasher (25), and flatwasher (24) from base cowling (31) and stay plate (37).  Remove stay plate.  Discard lockwasher. 10.  Remove oil cooler (see paragraph 4-17). 11.  Remove base cowling (31). b. CLEANING 1. Loosen dust and debris on duct (5), guide rail (6), shield (9), plate (16), base cowling (31), and stay plate (37) with brush. 4-64







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.