TM 5-4310-452-14 2-13.  STOPPING THE UNIT (Con't). WARNING Slowly  open  manual  blowdown  valve,  being  careful  to  keep  face  and  any  bare  skin  away  from valve opening.  If this warning is not followed, injury to personnel may result. CAUTION Never allow unit to sit idle with pressure in oil separator system.  If compressor is started with a charged air system, damage to compressor components could result. c. As soon as engine stops, check automatic blowdown valve (4) to ensure that all pressure  is  relieved  from  oil  separator  system. If   automatic   blowdown   valve   fails   to   operate, use    manual    blowdown    valve    (3)    to    relieve pressure from oil separator system. 2-19