3.  AIR DISCHARGE PRESSURE TOO LOW.
Table 4-3.  Electrical Troubleshooting Procedures

TM-5-4310-452-14 Compressor Air: Rotary Screw 750 CFM 100 PSI Wheel-Mounted DED SULLIAR Model 750 DP Manual
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
TM 5-4310-452-14 Table 4-2.  Mechanical Troubleshooting Procedures (Con't). MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 7. UNIT WILL NOT UNLOAD. Step 1.  Check for blocked regulating valve inlet. Remove and clean regulating valve (see paragraph 4-94). Step 2.  Check regulating valve adjustment. Adjust throttle control (see paragraph 4-25). Step 3.  Check for defective blowdown valve. Replace blowdown valve (see paragraph 4-95). 8.  SAFETY RELIEF VALVE RELIEVES. Step 1.  Check to see if safety valve pops off. Replace oil separator filter element (see paragraph 4-87). Step 2.  Check to see if operating pressure is too high. Adjust throttle control (see paragraph 4-25). Replace unloader valve assembly (see paragraph 4-90). Remove and clean regulating valve (see paragraph 4-94). Replace safety relief valve (see paragraph 4-96). 9.  START PRESSURE TOO HIGH. Step 1.  Check for blocked regulating valve inlet. Remove and clean regulating valve (see paragraph 4-94). Step 2.  Check for defective blowdown valve. Replace blowdown valve (see paragraph 4-95). 10.  EXCESSIVE VIBRATION. Step 1.  Check for loose fan hub. Tighten fan hub (see paragraph 4-92). Step 2.  Check for bent or broken fan blades, Replace fan (see paragraph 4-92). 4-14