• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Low discharge pressure and air delivery.
SECTION V. UNIT MAINTENANCE PROCEDURES

TM-55-1905-223-24-8 Air Compressor for Landing Craft Utility (LCU) Manual
Page Navigation
  13    14    15    16    17  18  19    20    21    22    23  
TM 55-1905-223-24-8
Table 2-2. Troubleshooting - CONT
Malfunction
Test or Inspection
Corrective Action
11. Low oil pressure.
STEP 1. Check for low oil level in crankcase.
Add oil to the proper level.
STEP 2. Check for leaks,
Tighten as necessary.
STEP 3. Check for plugged oil sump strainer.
Clean sump strainer and change oil.
STEP 4. Check for defective oil pressure gauge.
Replace gauge (paragraph 2-23).
STEP 5. Check oil viscosity.
Change oil.
12. Motor stalls.
STEP 1. Check for proper voltage to the motor with a multimeter.
If low voltage is found, check voltage at motor controller
(TM 55-1905-223-24-18).
STEP 2. Check for defective motor. Use multimeter and check windings for OPEN or SHORT.
Replace motor (paragraph 2-12).