Figure 5-2.  Fuel Injector Pump Repair and Replacement.
Figure 5-4.  Regulator Bracket Assembly Repair and Replacement.

TM-9-4310-394-13 Air Conditioner Vertical Compact 6 000 BTU/HR 115 Volt Single-Phase 50/60 Hertz Manual
Page Navigation
  108    109    110    111    112  113  114    115    116    117    118  
TM 9-4310-394-13 5-9.  REGULATOR BRACKET ASSEMBLY REPAIR AND REPLACEMENT. This task covers: a. Removal c. Repair e. Adjustment b. Inspection d. Installation INITIAL SETUP Tools Required Tool Kit, General Mechanic's (Appendix B, Item 1) Tachometer (Appendix B, Item 3) Materials/Parts Required Diesel Fuel (Appendix E, Item 5) Equipment Condition Air compressor unit shut down and cool. Fuel removed (see para.  4-18). a.    Removal.  (Refer to Figure 5-4). (1) Remove mounting bolts (1 and 2). (2) Remove regulator bracket (3) with regulator lever (4) and springs attached. (3) Remove regulator spring (5) from the governor lever (6) and regulator lever (4). (4) Remove return spring (7) from the governor lever (6) and regulator lever (4). (5) Remove regulator coil spring (8). (6) Remove regulator lever (4) from regulator bracket (3) by unscrewing lever locking knob (9) and lock nut (10). (7) Remove adjusting bolt (11) and nut (12). (8) Remove wire (13), bolt (14), and nut (15). b. Inspection. (1) Clean all parts with diesel fuel. (2) Inspect all components for damage or excessive wear.  Replace any components damaged or worn. c.    Repair.  Repair is limited to replacement of defective parts. d. Installation. (1) Install nut (11) and bolt (12). (2) Install nut (15) and adjusting bolt (14). (3) Install regulator coil spring (8). 5-10







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.