TM 9-4310-394-13 Table 4-1.  Unit Preventive Maintenance Checks and Services (PMCS). Interval Item Item to be No. M Q A Inspected Procedures 5 Starter Check that starter engages with engine to start engine properly.   During the starting procedure, listen for any grinding noises which may indicate an internal problem with the starter. 6 Lube Oil Strainer Remove bolt (1), O-ring (2) and lube oil strainer (3). Clean any dirt and debris that may have collected in the lube oil strainer (3). Check lube oil strainer (3) for damaged screen or cracked O-ring (2).  If repairs are required, refer to paragraph 4-31. Install lube oil strainer (3), O-ring (2) and bolt (1). 4-7