  123    124    125    126    127  128  129    130    131    132    133  
TM9-4310-396-13 c. Remove Check Valve. (1)    Loosen  tube  nuts  (1,  Figure  4-25)  and  remove  metallic  tube  (2)  from  pipe  elbow  (3)  and  reciprocating compressor. (2) Remove pipe elbow (3), pipe nipple (4), and check valve (5). Figure  4-25.  Check Valve and Drain Valve. d. Install Pilot Valve. NOTE Use teflon tape to tape threads of pilot valve. (1) Install pilot valve (4, Figure 4-24). (2) Install straight adapter (3), nonmetallic tubing (2), and tighten tube nut (1). e. Install Check Valve. NOTE Use teflon tape to tape threads of check valve and pipe nipple. (1) Install check valve (5, Figure 4-25). (2) Install pipe nipple (4) and pipe elbow (3). (3) Install metallic tube (2) and tube nuts (1) and tighten. 4-67